FLUKE 8505A PDF

Fluke A Digital Multimeter DIGIT Engineering Bench Precision OPT 02a 03 About this product. About this product. Product Identifiers. BRAND. Fluke. Full text of “FLUKE A Instruction”. See other formats. Instruction Manual P/N MARCH 1 REV 1, 3/86 ®, John Fluke Mfg. Co., Inc. All Rights. Active Filter Block Diagram A Fast A/D Converter The Fast A/ D Converter employs Fluke’s patented recirculating remainder (R2) technique.

Author: Kazizil Zuluramar
Country: Philippines
Language: English (Spanish)
Genre: Health and Food
Published (Last): 14 January 2010
Pages: 415
PDF File Size: 3.2 Mb
ePub File Size: 20.61 Mb
ISBN: 371-8-85586-751-8
Downloads: 64157
Price: Free* [*Free Regsitration Required]
Uploader: Mezitilar

Overrange points for each range are defined in Table Averaging AC Converter Option 2: This feature insures a reliable reading-in-progress indication at these slower reading rates. The first byte of this response contains sign and error bits, an implied binary point, and an implied scale factor of ten.

Store previous reading as scaling factor. Test Equipment When toggling off, no range change is effected. Slow filter, time-out enabled Fast filter, time-out enabled ms.

The read value may not be stored as a Scaling Factor.

This function can be used with the Current Shunts module installed. Selection of High Speed mode specifies the binary output format.

No stored scaling or offset value is lost in this manner. The exponent is range dependent in ohms function 1 for ohm ranges, 4 for kohm ranges, and 7 for 8550a ranges. Power must not be cycled on or off when the Calibration mode is activated rear panel Calibration Switch on. Select the desired function.

  BULLETIN OFFICIEL 5959 MAROC PDF

Fluke 8505A reference multimeter

All other modes and values are disabled. Measurement Ranges The multimeter automatically subtracts a 8505aa numeric or previously stored display value from the measurement and displays the result.

With regard to any instrument returned within 1 year of the original purchase, said repairs or replacement will be made without charge. If error 25 recurs during the clearing procedure or during any subsequent programming attempt, the Calibration Memory may be faulty. Data from the data bus is latched into the control circuitry and used to select relays in the attenuator and switched in the amplifier feedback circuit.

A comprehensive setup routine is summarized in 8505x Ranges available in each function are summarized in Table Fresh numerics may then be entered immediately. Slow 00 0O 00 00 Fast filter, time-out flukee.

Fluke A used or new for sale at used-line

Operating and programming instructions related to remote operation are included with the appropriate optional module. The Average mode is disabled OO.

Any of 18 different reading rates can be specified using the following push button sequence: Press PEAK to record measurement extremes. However, the zero value is stored in the following new fashion: BNC with the outer shell at interface common. SO commands ac volts normal. Programming Instructions cent An example of an illegal numeric string is: Four types of configuration change are therefore possible.

  ISABGOL CULTIVATION PDF

Using the arithmetic capability of the microprocessor, the software processes the data to arrive at a binary twos complement number which represents the polarity and value of the measurement. The instrument may be piaced in Remote mode by transmitting any character that the instrument wiil recognize from the remote controlling terminal.

Use a manual trigger for each measurement. All mathematic operations and special operations are disabled. Clearall of Calibration Memory. I recommend this meter as a good bench type meter for accurate measurement. If another G1 command is sent before a new reading is triggered, no error 00 is identified in the response.

Fluke 8505A Multimeters

There are two methods for making this selection. Response includes six digits with no leading zero suppression.

The instrument will then be in the defined state only; the character will not trigger a reading or produce a response from the instrument. Select valid function to clear error condition. The status response will be returned in the following seven character format. On receipt of the shipping instructions, forward the instrument transportation prepaid. For the A and A, a command string may have up to 59 characters. An averaging mode is available to automatically optimize display resolution and stability for each function and range.