CISPI 310 PDF

CISPI SPECIFICATION FOR COUPLING FOR USE IN CONNECTION WITH HUBLESS CAST IRON SOIL PIPE AND FITTINGS FOR SANITARY AND. NSF certified; Couplings meet/exceed material and performance requirements of ASTM C and CISPI ; Neoprene rubber gasket meets/exceeds ASTM C. Find the most up-to-date version of CISPI at Engineering

Author: Daigis Moogujar
Country: Uruguay
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 23 October 2007
Pages: 113
PDF File Size: 11.4 Mb
ePub File Size: 4.63 Mb
ISBN: 931-6-69848-693-5
Downloads: 76527
Price: Free* [*Free Regsitration Required]
Uploader: Junris

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

They are extra long to replace fittings cut out at the joint during a fix or alteration. The RNH Series of expansion joints are used to connect cast iron or plastic to cast iron or plastic pipe.

Generally, they have more clamps and provide a greater band load than standard no-hub couplings. Typically used to test gravity flow in non pressure DWV and sewer systems. This specification covers 3310 evaluating of the performance of shielded hubless couplings to join cast iron soil pipe and fittings.

All of our products are proudly made in the USA. Used to provide a positive and significant seal between no hub cast iron pipe and fittings. Physical properties of all stainless steel and gaskets shall comply with the specified values. Innovative product designs save the installer time and material cost and provides the owner with higher quality cast stainless steel drains and cleanouts for the same cost as the industry standard nickel bronze.

Link to Active This link will always route to the current Active version of the standard. Contact us today to learn more.

Std No-Hub Couplings

Specification for coupling for use in connection with hubless cast iron pipe and fittings for sanitary and storm drain, waste, and vent piping application Regular hubless coupling Scope: Hose bibb provides a water supply. This specification covers the performance evaluation of heavy duty shielded couplings to join hubless cast iron soil pipe and fittings.

  CARLIN SOSKICE MACROECONOMICS IMPERFECTIONS INSTITUTIONS POLICIES PDF

They are normally installed using a torque wrench. Privacy Policy Terms of Use Follow us: MI-FLEX Series of flexible rubber couplings are used to connect cast iron, plastic, steel or lead pipe to cast iron, plastic, steel or lead pipe.

ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. This standard does not purport to address all of the safety concerns, if any, associated with its use. The test apparatus for deflection test, shear test, and unrestrained hydrostatic joint test are illustrated.

Tyler 4″ No Hub Coupling B NSF Cisp | eBay

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. They are tested to maintain 4. Requirements for the elastomeric gasket, clamp assembly, and couplings such as coupling width are detailed.

MI-HUB-TR Series of shielded transition couplings are used to connect cast iron, plastic or steel pipe to cast iron, plastic or steel pipe. Used to cap pipe ends, cleanouts and open pipes. Support One of the added benefits of using Charlotte Pipe is the many resources we provide. Tested to maintain 4. Intended for use with DWV systems, no-hub couplings are used to join cast iron soil pipe that does not have the traditional Hub and Spigot. One of the added benefits of using Charlotte Pipe is the many resources we provide.

Historical Version s – view previous versions of standard. Made in the USA For over a century, Charlotte Pipe has been manufacturing pipe and fittings, employing more than 1, loyal, hard-working Americans.

  DASAR TEORI AYUNAN MATEMATIS PDF

Non constant temperature rating is F.

It is the responsibility of the user of this standard cisip establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. The plastic plug will expand into the pipe opening as it is tightened. The purpose of this specification is to establish criteria for material dimensions and tolerances for one type of coupling used in hubless cast iron soil pipe and fitting for sanitary and storm drain, waste and vent piping applications.

The purpose of this specification is to establish criteria for material dimensions and tolerances of heavy duty shielded couplings to join hubless cast iron cisoi pipe and fittings in sanitary and storm drain, waste and vent piping applications.

Medium and Heavy Duty Couplings Intended for use with DWV systems, no-hub couplings are used to join cast iron soil pipe that does not have the traditional Hub and Spigot. Specification for shielded couplings joining hubless cast iron soil pipe and fittings Scope: For over a century, Charlotte Pipe has been manufacturing pipe and fittings, employing more than 1, loyal, hard-working Americans.

Tighten bolts to 60 inch lbs.

This abstract is a brief summary of the referenced standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Click for specsheet Click for downloads List Prices.